1. Determination of the specific activities of methionine sulfoxide reductase A and B by capillary electrophoresis
Eric O Uthus Anal Biochem. 2010 Jun 1;401(1):68-73. doi: 10.1016/j.ab.2010.02.013. Epub 2010 Feb 16.
A capillary electrophoresis (CE) method for the determination of methionine sulfoxide reductase A and methionine sulfoxide reductase B activities in mouse liver is described. The method is based on detection of the 4-(dimethylamino)azobenzene-4'-sulfonyl derivative of l-methionine (dabsyl Met), the product of the enzymatic reactions when either dabsyl l-methionine S-sulfoxide or dabsyl l-methionine R-sulfoxide is used as a substrate. The method provides baseline resolution of the substrates and, therefore, can be used to easily determine the purity of the substrates. The method is rapid ( approximately 20min sample to sample), requires no column regeneration, and uses very small amounts of buffers. Separation was performed by using a 75-mum internal diameter polyimide-coated fused silica capillary (no inside coating) with 60cm total length (50cm to the detector window). Samples were separated at 22.5kV, and the separation buffer was 25mM KH(2)PO(4) (pH 8.0) containing 0.9ml of N-lauroylsarcosine (sodium salt, 30% [w/v] solution) per 100ml of buffer. Prior to use, the capillary was conditioned with the same buffer that also contained 25mM sodium dodecyl sulfate. The CE method is compared with high-performance liquid chromatography (HPLC) as determined by comparing results from measurements of hepatic enzyme activities in mice fed either deficient or adequate selenium.
2. Experimental design-guided development of a stereospecific capillary electrophoresis assay for methionine sulfoxide reductase enzymes using a diastereomeric pentapeptide substrate
Qingfu Zhu, Xingyu Huo, Stefan H Heinemann, Roland Schönherr, Rabab El-Mergawy, Gerhard K E Scriba J Chromatogr A. 2014 Sep 12;1359:224-9. doi: 10.1016/j.chroma.2014.07.009. Epub 2014 Jul 12.
A capillary electrophoresis method has been developed and validated to evaluate the stereospecific activity of recombinant human methionine sulfoxide reductase enzymes employing the C-terminally dinitrophenyl-labeled N-acetylated pentapeptide ac-KIFM(O)K-Dnp as substrate (M(O)=methionine sulfoxide). The separation of the ac-KIFM(O)K-Dnp diastereomers and the reduced peptide ac-KIFMK-Dnp was optimized using experimental design with regard to the buffer pH, buffer concentration, sulfated β-cyclodextrin and 15-crown-5 concentration as well as capillary temperature and separation voltage. A fractional factorial response IV design was employed for the identification of the significant factors and a five-level circumscribed central composite design for the final method optimization. Resolution of the peptide diastereomers as well as analyte migration time served as responses in both designs. The resulting optimized conditions included 50mM Tris buffer, pH 7.85, containing 5mM 15-crown-5 and 14.3mg/mL sulfated β-cyclodextrin, at an applied voltage of 25kV and a capillary temperature of 21.5°C. The assay was subsequently applied to the determination of the stereospecificity of recombinant human methionine sulfoxide reductases A and B2. The Michaelis-Menten kinetic data were determined. The pentapeptide proved to be a good substrate for both enzymes. Furthermore, the first separation of methionine sulfoxide peptide diastereomers is reported.
3. Stereospecific micellar electrokinetic chromatography assay of methionine sulfoxide reductase activity employing a multiple layer coated capillary
Qingfu Zhu, Rabab G El-Mergawy, Stefan H Heinemann, Roland Schönherr, Pavel Jáč, Gerhard K E Scriba Electrophoresis. 2013 Sep;34(18):2712-7. doi: 10.1002/elps.201300147. Epub 2013 Aug 9.
A micellar electrokinetic chromatography method for the analysis of the l-methionine sulfoxide diastereomers employing a successive multiple ionic-polymer layer coated fused-silica capillary was developed and validated in order to investigate the stereospecificity of methionine sulfoxide reductases. The capillary coating consisted of a first layer of hexadimethrine and a second layer of dextran sulfate providing a stable strong cathodic EOF and consequently highly repeatable analyte migration times. The methionine sulfoxide diastereomers, methionine as product as well as β-alanine as internal standard were derivatized by dabsyl chloride and separated using a 35 mM sodium phosphate buffer, pH 8.0, containing 25 mM SDS as BGE and a separation voltage of 25 kV. The method was validated in the range of 0.15-2.0 mM with respect to linearity and precision. The LODs of the analytes ranged between 0.04 and 0.10 mM. The assay was subsequently applied to determine the stereospecificity of methionine sulfoxide reductases as well as the enzyme kinetics of human methionine sulfoxide reductase A. Monitoring the decrease of the l-methionine-(S)-sulfoxide Km = 411.8 ± 33.8 μM and Vmax = 307.5 ± 10.8 μM/min were determined.